Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-4 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	53
Date	08/04/14
Start Time	11:45:34
Diameter Midpoint
 11.3	311002
 11.8	294386
 12.2	309767
 12.6	329725
 13.1	353595
 13.6	385297
 14.1	416215
 14.6	442565
 15.1	469910
 15.7	509051
 16.3	546027
 16.8	580175
 17.5	611891
 18.1	649918
 18.8	683033
 19.5	716150
 20.2	748766
 20.9	761697
 21.7	778565
 22.5	806942
 23.3	827845
 24.1	840020
 25.0	844798
 25.9	835285
 26.9	830597
 27.9	806061
 28.9	780775
 30.0	750503
 31.1	724621
 32.2	679808
 33.4	638973
 34.6	596021
 35.9	547418
 37.2	499226
 38.5	444662
 40.0	392918
 41.4	343775
 42.9	301139
 44.5	260079
 46.1	225469
 47.8	193631
 49.6	162156
 51.4	133482
 53.3	108304
 55.2	88511
 57.3	71166.5
 59.4	58597.9
 61.5	49411
 63.8	40494.5
 66.1	34096.8
 68.5	30941.9
 71.0	30412.3
 73.7	29716.4
 76.4	28543.5
 79.1	25906.9
 82.0	22094.3
 85.1	18200.7
 88.2	14382.5
 91.4	10902.2
 94.7	8262.97
 98.2	5976.74
101.8	4541.45
105.5	3460.26
109.4	2556.33
113.4	2051.14
117.6	1557.39
121.9	1150.97
126.3	954.239
131.0	786.559
135.8	687.963
140.7	545.016
145.9	501.052
151.2	452.005
156.8	400.096
162.5	314.268
168.5	316.683
174.7	212.134
181.1	198.92
187.7	205.989
194.6	167.67
201.7	135.099
209.1	118.983
216.7	120.467
224.7	96.0376
232.9	97.3531
241.4	98.0016
250.3	90.2746
259.5	91.2662
269.0	83.6256
278.8	102.765
289.0	69.1334
299.6	71.6385
310.6	79.6246
322.0	56.6644
333.8	47.5153
346.0	59.4904
358.7	34.9654
371.8	57.4867
385.4	43.6463
399.5	27.8955
414.2	44.2794
429.4	31.2271
445.1	41.1879
461.4	19.2999
478.3	33.7393
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.7136
High Voltage	9978
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1081.44
Median(nm)	24.2335
Mean(nm)	26.423
Geo. Mean(nm)	24.3409
Mode(nm)	25.0287
Geo. Std. Dev.	1.48721
Total Concentration(#/cm)	2.40627e+007
Comment	